Technical guide
WL15 vs WL20 Lanthanated Tungsten
Both are lanthanated, both run AC and DC, both are the modern non-radioactive default. The difference is oxide content — and that changes arc start and high-current behaviour.
Head to head
| Property | WL15 (gold) | WL20 (blue) |
|---|---|---|
| La2O3 content | 1.3–1.7 % | 1.8–2.2 % |
| ISO 6848 colour | gold | blue |
| Arc start at low current | very good | excellent |
| High-current tip life | good | better |
| AC aluminium | yes | yes |
| DC steel / stainless | yes | yes |
Which to stock
WL20's higher lanthana gives slightly easier starts and longer tip life at higher current, which is why it has become the most-stocked single grade. WL15 is a touch more forgiving on very thin, low-amp work and is often cheaper. For a distributor, stocking WL20 as the default and WL15 as the low-amp option covers most demand without carrying both thoriated and ceriated lines.
Against thoriated and ceriated
Lanthanated grades replace WT20 for most DC work without the radioactivity handling, and outperform WC20 at higher current. See WT20 vs WC20 and the color chart. For AC aluminium, compare WZ8.